亚洲性爱视频在线无码,精品人妻无码久久久久久,免费观看成人成视频大全,色综合久久无码中文字幕APP,国产日韩一区在线观看视频

Welcome to Changzhou Jianghua Electrical Machinery Co., Ltd

National service hotline: 0519-88354306

JH-DM872H stepping motor driver

全國服務熱線: 13706125925

我要詢價

產品描述

·Product Overview

JH-DM872H uses a 32-bit processor as the operation core, with a variety of current and subdivision settings, which can meet the application needs of most occasions. Because of the built-in subdivision technology, the effect of high subdivision can be achieved even under the condition of low subdivision. The low, medium and high speed operation is very stable, and the noise is extremely small. The driver has the function of motor parameter learning and automatic tuning of control parameters, as well as the change of fine tuning and adaptive parameters during operation. It can automatically generate operating parameters for different motors to maximize the performance of the motor.

characteristic

● Wide voltage, both AC and DC input, AC input range: AC20V-AC90V

● Intelligent current control, improve dynamic Q value, greatly reduce motor heating

● Adaptive smoothing function, good low-speed stability and low noise.

● Vector control technology, high speed torque.

● Anti resonance technology can easily break through the medium speed resonance zone, with good characteristics of medium and high speed.

● The improved PWM control algorithm makes the motor and driver generate less heat.

● No obvious noise and vibration when switching from full flow to half flow.

● Capable of driving 4, 6 and 8 wire two-phase stepping motor

● Optical isolation differential signal input

● Pulse response frequency can reach 200KHz

● Convenient current setting

● It has overvoltage, undervoltage, short circuit and other protection functions

·Main application fields

Suitable for all kinds of small and medium-sized automatic equipment and instruments, such as engraving machines, marking machines, cutting machines, laser processing, CNC machine tools, automatic assembly equipment, etc. The utility model has the advantages of low cost, low noise and high speed.

Driver Function Description

Drive function

Operating Instructions

Microstep number setting

The driver microstep number is set by four SW5-SW8 dial switches, which have 15 microstep numbers in total. When the user sets the micro step subdivision, the driver should be stopped first. Please refer to the layout of the driver for detailed microstep number settings.

Output current setting

The output current of the driver is set by the three dial switches SW1-SW3. The output current has 8 levels. For specific output current settings, please refer to the layout of the driver.

Automatic half flow function

The user can set the automatic half flow function of the driver through SW4. Off indicates that the static current is set to half of the dynamic current, and on indicates that the static current is the same as the dynamic current. In general use, SW4 should be set as off to reduce the heating of motor and driver and improve the reliability. About 0.4 seconds after the pulse train stops, the current automatically reduces to about half (60% of the actual value), and the calorific value theoretically reduces to 36%.

Signal interface

PUL + and PUL - are the positive and negative ends of the control pulse signal; DIR + and DIR - are positive and negative terminals of direction signal; ENA + and ENA - positive and negative terminals of enable signal.

Motor interface

A + and A - connected to the positive and negative ends of phase A winding of stepping motor; B+and B - connected to the positive and negative ends of phase B winding of stepping motor. When A and B windings are exchanged, the motor direction can be reversed.

Power interface

AC or DC power supply is adopted. The recommended working voltage range is: DC36 - 110VDC, or AC20-AC90V. The power supply power is greater than 300W.

indicator light

The drive has two red and green indicators. The green light is the power indicator, which is always on when the driver is powered on; The red lamp is a fault indicator lamp. When overvoltage and overcurrent faults occur, the fault lamp is always on. After the fault is cleared, the red light is off. When the drive fails, the fault can be cleared only by re powering on and re enabling.

Installation Instructions

The overall dimensions of the drive are: 151 × ninety-seven × 48mm, and the installation hole spacing is 143mm. Both horizontal and vertical installation can be adopted, and vertical installation is recommended. During installation, it shall be closely attached to the metal cabinet to facilitate heat dissipation.

Parameter setting

JH-DM872A driver uses 8-bit dial switch to set subdivision accuracy, dynamic current and half current/full current. The detailed description is as follows:


 

Working current setting

Output current

Reference current

SW1

SW2

SW3

2.40A

1.70A

on

on

on

3.08A

2.18A

off

on

on

3.77A

2.66A

on

off

on

4.45A

3.15A

off

off

on

5.14A

3.63A

on

on

off

5.83A

4.12A

off

on

off

6.52A

4.61A

on

off

off

7.20A

5.10A

off

off

off

Microstep tessellation settings

Steps/revolution

SW5

SW6

SW7

SW8

400

off

on

on

on

800

on

off

on

on

1600

off

off

on

on

3200

on

on

off

on

6400

off

on

off

on

12800

on

off

off

on

25600

off

off

off

on

1000

on

on

on

off

2000

off

on

on

off

4000

on

off

on

off

5000

off

off

on

off

8000

on

on

off

off

10000

off

on

off

off

20000

on

off

off

off

25000

off

off

off

off

Installation dimensions

 

 


相關產品